Specifications | |
Main | |
Range | TeSys |
Range of Product | TeSys Deca |
Product or Component Type | Contactor |
Device short name | LC1D |
contactor application | Resistive load |
Resistive load | |
Utilisation category | AC-2 |
AC-4 | |
AC-3 | |
AC-3e | |
AC-4 | |
poles description | 3P |
[Ue] rated operational voltage | Power circuit <= 690 V AC 25…400 Hz |
[Ie] rated operational current | 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit | |
50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit | |
[Uc] control circuit voltage | 24 V DC |
Complementary | |
Motor power kW | 25 kW at 415 V AC 50 Hz (AC-3) |
30 kW at 440 V AC 50 Hz (AC-3) | |
30 kW at 500 V AC 50 Hz (AC-3) | |
33 kW at 660…690 V AC 50 Hz (AC-3) | |
15 kW at 220…230 V AC 50 Hz (AC-3) | |
11 kW at 400 V AC 50 Hz (AC-4) | |
30 kW at 1000 V AC 50 Hz (AC-3) | |
22 kW at 380…400 V AC 50 Hz (AC-3e) | |
25 kW at 415 V AC 50 Hz (AC-3e) | |
30 kW at 440 V AC 50 Hz (AC-3e) | |
30 kW at 500 V AC 50 Hz (AC-3e) | |
33 kW at 660…690 V AC 50 Hz (AC-3e) | |
15 kW at 220…230 V AC 50 Hz (AC-3e) | |
30 kW at 1000 V AC 50 Hz (AC-3e) | |
22 kW at 380…400 V AC 50 Hz (AC-3) | |
Maximum Horse Power Rating | 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors |
15 hp at 200/208 V AC 60 Hz for 3 phase motors | |
15 hp at 230/240 V AC 60 Hz for 3 phase motors | |
40 hp at 460/480 V AC 60 Hz for 3 phase motors | |
40 hp at 575/600 V AC 60 Hz for 3 phase motors | |
3 hp at 115 V AC 60 Hz for 1 phase motors | |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 80 A (at 140 °F (60 °C)) for power circuit |
10 A (at 140 °F (60 °C)) for control circuit | |
Irms rated making capacity | 900 A at 440 V DC for power circuit conforming to IEC 60947 |
900 A at 440 V for power circuit conforming to IEC 60947 | |
250 A DC for control circuit conforming to IEC 60947-5-1 | |
Rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
Associated fuse rating | 100 A gG at <= 690 V coordination type 1 for power circuit |
100 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 | |
10 A gG for control circuit conforming to IEC 60947-5-1 | |
Power dissipation per pole | 9.6 W AC-1 |
3.7 W AC-3e | |
3.7 W AC-3 | |
[Ui] rated insulation voltage | Control circuit 600 V UL |
Power circuit 600 V CSA | |
Power circuit 600 V UL IEC 60947-1 | |
Control circuit 690 V IEC 60947-1 | |
Power circuit 690 V IEC 60947-1 | |
Power circuit 1000 V CSA IEC 60947-4-1 | |
Control circuit 600 V CSA | |
Overvoltage category | III |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 | |
Mechanical durability | 10000000 cycles |
Control circuit type | DC wide range |
Coil technology | Built-in bidirectional peak limiting diode suppressor |
Control circuit voltage limits | 0.75…1.25 Uc -40…140 °F (-40…60 °C) operational DC |
1…1.25 Uc 140…158 °F (60…70 °C) operational DC | |
0.1…0.3 Uc -40…158 °F (-40…70 °C) drop-out DC | |
Inrush power in W | 19 W 68 °F (20 °C)) |
Hold-in power consumption in W | 7.4 W 68 °F (20 °C) |
Rated operational power in W | 48 W 24 V DC-13 3000000 cycles – control circuit |
96 W 24 V DC-13 1000000 cycles – control circuit | |
14 W 24 V DC-13 10000000 cycles – control circuit | |
Operating time | 50 ±15 % ms closing |
20 ±20 % ms opening | |
Time constant | 34 ms |
Maximum operating rate | 3600 cyc/h 140 °F (60 °C) |
Connections – terminals | Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) – cable stiffness: rigid without cable end |
Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) – cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) – cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible with cable end | |
Control circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible with cable end | |
Power circuit: screw terminals 1 0.00…0.04 in² (2.5…25 mm²) – cable stiffness: rigid | |
Power circuit: screw terminals 2 0.00…0.02 in² (2.5…16 mm²) – cable stiffness: rigid without cable end | |
Power circuit: screw terminals 1 0.00…0.04 in² (2.5…25 mm²) – cable stiffness: flexible without cable end | |
Power circuit: screw terminals 2 0.00…0.02 in² (2.5…16 mm²) – cable stiffness: flexible without cable end | |
Power circuit: screw terminals 1 0.00…0.04 in² (2.5…25 mm²) – cable stiffness: flexible with cable end | |
Power circuit: screw terminals 2 0.00…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end | |
Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) – cable stiffness: rigid | |
Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) – cable stiffness: rigid | |
Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2 |
Power circuit 44.25 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm | |
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2 | |
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm | |
auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Mirror contact 1 NC IEC 60947-4-1 |
Mechanically linked 1 NO + 1 NC IEC 60947-5-1 | |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on energisation between NC and NO contacts |
1.5 ms on de-energisation between NC and NO contacts | |
Mounting Support | Plate |
Plate | |
Environment | |
Standards | CSA C22.2 No 14 |
IEC 60947-5-1 | |
EN 60947-4-1 | |
EN 60947-5-1 | |
IEC 60947-4-1 | |
Product Certifications | CSA |
DNV | |
RINA | |
BV | |
CCC | |
UL | |
GOST | |
GL | |
UKCA | |
CCC | |
IP degree of protection | IP2X VDE 0106 |
IP2X IEC 60529 | |
Climatic withstand | IACS E10 exposure to damp heat |
Operating altitude | 0…9842.52 ft (0…3000 m) |
Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Shocks contactor closed 15 Gn for 11 ms) |
Vibrations contactor opened 2 Gn, 5…300 Hz) | |
Vibrations contactor closed 4 Gn, 5…300 Hz) | |
Shocks contactor opened 10 Gn for 11 ms) | |
Height | 5.00 in (127 mm) |
Width | 3.35 in (85 mm) |
Depth | 6.93 in (176 mm) |
Net Weight | 4.82 lb(US) (2.185 kg) |
Ordering and shipping details | |
Category | US10I1222358 |
Discount Schedule | 0I12 |
GTIN | 3.38911E+12 |
Returnability | Yes |
Country of origin | CZ |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 3.54 in (9.0 cm) |
Package 1 Width | 5.51 in (14.0 cm) |
Package 1 Length | 7.28 in (18.5 cm) |
Package 1 Weight | 4.78 lb(US) (2.169 kg) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 2 |
Package 2 Height | 5.91 in (15 cm) |
Package 2 Width | 11.81 in (30 cm) |
Package 2 Length | 15.75 in (40 cm) |
Package 2 Weight | 10.65 lb(US) (4.829 kg) |
Contractual warranty | |
Warranty | 18 months |
Sale!
50A, 1NC+1NO, 24V DC Magnetic Contactor (MC) -Schneider Electric
Original price was: ৳ 30,070.00.৳ 21,049.00Current price is: ৳ 21,049.00.
& Delivery/Courier ChargeDocuments: Product datasheet, Instruction sheet, CAD file
Free Delivery on orders over ৳50,000!
- Cash on delivery
- 1-3 Days Standard Delivery Guaranteed
- No-Risk Money Back Guarantee!
- No Hassle Refunds
- Secure Payments
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.