150A , Ith 250A , Magnetic Contactor (MC)-Schneider Electric

Original price was: ৳ 38,150.00.Current price is: ৳ 26,705.00.

& Delivery/Courier Charge
Category:

Free Delivery on orders over ৳50,000!

  • Cash on delivery
  • 1-3 Days Standard Delivery Guaranteed
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel.

Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard.

The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications
Main
RangeTeSys
Range of ProductTeSys Deca
Product or Component TypeContactor
Device short nameLC1D
contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-4
AC-1
AC-3e
poles description3P
[Ue] rated operational voltagePower circuit <= 1000 V AC 25…400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Motor power kW40 kW at 220…230 V AC 50/60 Hz (AC-3)
75 kW at 380…400 V AC 50/60 Hz (AC-3)
80 kW at 415…440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660…690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
22 kW at 400 V AC 50/60 Hz (AC-4)
40 kW at 220…230 V AC 50/60 Hz (AC-3e)
75 kW at 380…400 V AC 50/60 Hz (AC-3e)
80 kW at 415…440 V AC 50/60 Hz (AC-3e)
90 kW at 500 V AC 50/60 Hz (AC-3e)
100 kW at 660…690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating40 hp at 200/208 V AC 50/60 Hz for 3 phase motors
50 hp at 230/240 V AC 50/60 Hz for 3 phase motors
100 hp at 460/480 V AC 50/60 Hz for 3 phase motors
125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current200 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current250 A 104 °F (40 °C) – 10 min for power circuit
580 A 104 °F (40 °C) – 1 min for power circuit
1200 A 104 °F (40 °C) – 10 s for power circuit
1400 A 104 °F (40 °C) – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.6 mOhm – Ith 200 A 50 Hz for power circuit
Power dissipation per pole24 W AC-1
13.5 W AC-3
13.5 W AC-3e
[Ui] rated insulation voltagePower circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV IEC 60947
Safety reliability levelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1
B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability8 Mcycles
Electrical durability0.85 Mcycles 150 A AC-3 <= 440 V
1 Mcycles 200 A AC-1 <= 440 V
0.85 Mcycles 150 A AC-3e <= 440 V
Control circuit typeAC 50/60 Hz standard
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.3…0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz
1…1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
Inrush power in VA280…350 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C))
280…350 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C))
Hold-in power consumption in VA2…18 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C))
2…18 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C))
Heat dissipation3…4.5 W at 50/60 Hz
Operating time20…35 ms closing
40…75 ms opening
Maximum operating rate1200 cyc/h 140 °F (60 °C)
Connections – terminalsControl circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: solid without cable end
Power circuit: connector 1 0.02…0.19 in² (10…120 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 1 0.02…0.19 in² (10…120 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 1 0.02…0.19 in² (10…120 mm²) – cable stiffness: solid without cable end
Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) – cable stiffness: solid without cable end
Tightening torqueControl circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeMechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting SupportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product CertificationsCCC
LROS (Lloyds register of shipping)
GL
GOST
RINA
CSA
BV
UL
DNV
UKCA
CE
IP degree of protectionIP20 front face IEC 60529
Protective treatmentTHIEC 60068-2-30
Climatic withstandIACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude0…9842.52 ft (0…3000 m)
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open 2 Gn, 5…300 Hz)
Vibrations contactor closed 4 Gn, 5…300 Hz)
Shocks contactor closed 15 Gn for 11 ms)
Shocks contactor open 6 Gn for 11 ms)
Height6.22 in (158 mm)
Width4.72 in (120 mm)
Depth5.35 in (136 mm)
Net Weight5.51 lb(US) (2.5 kg)
Ordering and shipping details
CategoryUS10I1222359
Discount Schedule0I12
GTIN3.38911E+12
ReturnabilityYes
Country of originUS
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.27 in (21.000 cm)
Package 1 Width7.87 in (20.000 cm)
Package 1 Length9.25 in (23.500 cm)
Package 1 Weight5.49 lb(US) (2.490 kg)
Unit Type of Package 2S06
Number of Units in Package 227
Package 2 Height29.53 in (75.000 cm)
Package 2 Width23.62 in (60.000 cm)
Package 2 Length31.50 in (80.000 cm)
Package 2 Weight175.97 lb(US) (79.819 kg)
Contractual warranty
Warranty18 months

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shopping Cart
150A (AC3), 3P, Ith 250A (AC1), MC, Coil : 220/415/110/24 V AC, IEC Contractor-Schneider Electric150A , Ith 250A , Magnetic Contactor (MC)-Schneider Electric
Original price was: ৳ 38,150.00.Current price is: ৳ 26,705.00.
Scroll to Top