The MS116-25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 10 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

MAIN SPECIFICATION
ABB Global ID ABB1SAM250000R1014
Business Area (Master Data) Name Electrification
Catalog Description MS116-25 Manual Motor Starter Trip class 10A, 20 … 25 A
Division (Master Data) Name Smart Power
EAN 4.01361E+12
Rated Insulation Voltage (Ui) 690 volt
Rated Operation Current 25 ampere
SKU ID 1SAM250000R1014
TECHNICAL
Connecting Capacity Main Circuit Flexible with Ferrule 1/2x 0.75 … 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 … 6 mm²
Flexible 1/2x 1 … 2.5 mm²
Flexible 1/2x 2.5 … 6 mm²
Rigid 1/2x 1 … 2.5 mm²
Rigid 1/2x 2.5 … 6 mm²
Contact Position Indication ON / OFF
Conventional Free-air Thermal Current (Ith) Main Circuit 25 A
Electrical Durability 50000 cycle
Mechanical Durability 100000 cycle
Minimum Mounting Distance Electrical Conductive Board, Horizontal – Up to 400 V 0 mm
Electrical Conductive Board, Horizontal – Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Mounting On DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position Position 1 to 6
Pollution Degree 3
Power Loss at Rated Operating Conditions per Pole 1.8 W
Rated Frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Instantaneous Short-Circuit Current Setting (Ii) 375 A
Rated Operational Current (Ie) 25 A
Rated Operational Current AC-3e (Ie) 25 A
Rated Operational Power AC-3e (Pe) (400 V) Three Phase 11 kW
Recommended Screw Driver Pozidriv 2
Standards IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Terminal Type Screw Terminals
Tightening Torque Main Circuit 2 N·m
Wire Stripping Length Main Circuit 10 mm
TECHNICAL UL/CSA
Ampere Rating UL/CSA 25 A
Connecting Capacity Main Circuit UL/CSA Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Full Load Amps Motor Use (200 V AC) Three Phase 17.5 A
(208 V AC) Three Phase 24.2 A
(220 … 240 V AC) Three Phase 22 A
(440 … 480 V AC) Three Phase 21 A
(550 … 600 V AC) Three Phase 22 A
General Use Rating UL/CSA (600 V AC) 25 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 5 Hp
(208 V AC) Three Phase 7.5 Hp
(220 … 240 V AC) Three Phase 7.5 Hp
(440 … 480 V AC) Three Phase 15 Hp
(550 … 600 V AC) Three Phase 20 Hp
Locked Rotor Amps (200 V AC) Three Phase 105.8 A
(208 V AC) Three Phase 140 A
(220 … 240 V AC) Three Phase 127 A
(440 … 480 V AC) Three Phase 116 A
(550 … 600 V AC) Three Phase 116 A
Maximum Operating Voltage UL/CSA Main Circuit 600 V AC
Short-Circuit Current Rating (SCCR) Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Tightening Torque UL/CSA Main Circuit 18 in·lb
ORDERING
Minimum Order Quantity 1 piece
ENVIRONMENTAL
Ambient Air Temperature Compensation Yes
Maximum Operating Altitude Permissible 2000 m
Resistance To Shock Acc. To IEC 60068-2-27 11 ms Pulse 25g
Resistance To Vibrations Acc. To IEC 60068-2-6 5g / 3 … 150 Hz
RoHS Status Following EU Directive 2011/65/EU
CLASSIFICATIONS
E-Number (Finland) 3705874
E-Number (Sweden) 3111952
EClass V11.0 : 27370401
ETIM 4 EC000074 – Motor protective circuit-breaker
ETIM 5 EC000074 – Motor protective circuit-breaker
ETIM 6 EC000074 – Motor protection circuit-breaker
ETIM 7 EC000074 – Motor protection circuit-breaker
IDEA Granular Category Code (IGCC) 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
Object Classification Code F
UNSPSC 39121521
OTHER
Actuator Type Rotary Handle
Ambient Air Temperature Around the Enclosure 0 … +40 °C
Operation -25 … +70 °C
Operation Compensated -25 … +55 °C
Storage -50 … +80 °C
Degree Of Protection Housing IP20
Main Circuit Terminals IP10
Number Of Poles 3
Product Net Width 45
Rated Impulse Withstand Voltage (Uimp) Main Circuit 6 kilovolt
Rated Operational Current AC-3 (Ie) 25 A
Rated Operational Power AC-3 (Pe) (400 V) Three Phase 11 kW
Rated Operational Voltage Main Circuit 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 10 kA
(400 V AC) 10 kA
(440 V AC) 3 kA
(500 V AC) 3 kA
(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 16 kA
(400 V AC) 16 kA
(440 V AC) 15 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
Setting Range 20 … 25 A