The MS116-0.63 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.63 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
MAIN SPECIFICATION | |
ABB Global ID | ABB1SAM250000R1004 |
Business Area (Master Data) Name | Electrification |
Catalog Description | MS116-0.63 Manual Motor Starter Trip class 10A, 0.4 … 0.63A |
Division (Master Data) Name | Smart Power |
EAN | 4013614320279 |
Rated Insulation Voltage (Ui) | 690 volt |
Rated Operation Current | 0.63 ampere |
SKU ID | 1SAM250000R1004 |
TECHNICAL | |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² |
Flexible with Insulated Ferrule 1/2x 0.75 … 2.5 mm² | |
Flexible 1/2x 0.75 … 2.5 mm² | |
Rigid 1/2x 1 … 4 mm² | |
Contact Position Indication | ON / OFF |
Conventional Free-air Thermal Current (Ith) | Main Circuit 0.63 A |
Electrical Durability | 100000 cycle |
Mechanical Durability | 100000 cycle |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal – Up to 400 V 0 mm |
Electrical Conductive Board, Horizontal – Up to 690 V 1.5 mm | |
Electrical Conductive Board, Vertical 75 mm | |
Other Device Same Type, Horizontal 0 mm | |
Other Device Same Type, Vertical 150 mm | |
Mounting On DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Mounting Position | Position 1 to 6 |
Pollution Degree | 3 |
Power Loss | at Rated Operating Conditions per Pole 0.7 W |
Rated Frequency (f) | Main Circuit 50 Hz |
Main Circuit 60 Hz | |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 7.9 A |
Rated Operational Current (Ie) | 0.63 A |
Rated Operational Current AC-3e (Ie) | 0.63 A |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 0.18 kW |
Recommended Screw Driver | Pozidriv 2 |
Standards | IEC/EN 60947-1 |
IEC/EN 60947-2 | |
IEC/EN 60947-4-1 | |
UL 60947-1 | |
UL 60947-4-1 | |
Terminal Type | Screw Terminals |
Tightening Torque | Main Circuit 0.8 … 1.2 N·m |
Wire Stripping Length | Main Circuit 9 mm |
TECHNICAL UL/CSA | |
Ampere Rating UL/CSA | 0.63 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-12 AWG |
Stranded 1/2x 16-12 AWG | |
Full Load Amps Motor Use | (110 … 120 V AC) Three Phase 0.63 A |
(200 V AC) Three Phase 0.63 A | |
(208 V AC) Three Phase 0.63 A | |
(220 … 240 V AC) Three Phase 0.63 A | |
(440 … 480 V AC) Three Phase 0.63 A | |
(550 … 600 V AC) Three Phase 0.63 A | |
General Use Rating UL/CSA | (600 V AC) 0.63 A |
Locked Rotor Amps | (110 … 120 V AC) Three Phase 3.78 A |
(200 V AC) Three Phase 3.78 A | |
(208 V AC) Three Phase 3.78 A | |
(220 … 240 V AC) Three Phase 3.78 A | |
(440 … 480 V AC) Three Phase 3.78 A | |
(550 … 600 V AC) Three Phase 3.78 A | |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA |
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA | |
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA | |
Tightening Torque UL/CSA | Main Circuit 10 in·lb |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Ambient Air Temperature Compensation | Yes |
Maximum Operating Altitude Permissible | 2000 m |
Resistance To Shock Acc. To IEC 60068-2-27 | 11 ms Pulse 25g |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5g / 3 … 150 Hz |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 3706004 |
E-Number (Sweden) | 3111936 |
EClass | V11.0 : 27370401 |
ETIM 4 | EC000074 – Motor protective circuit-breaker |
ETIM 5 | EC000074 – Motor protective circuit-breaker |
ETIM 6 | EC000074 – Motor protection circuit-breaker |
ETIM 7 | EC000074 – Motor protection circuit-breaker |
IDEA Granular Category Code (IGCC) | 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers |
Object Classification Code | F |
UNSPSC | 39121521 |
OTHER | |
Actuator Type | Rotary Handle |
Ambient Air Temperature | Around the Enclosure 0 … +40 °C |
Operation -25 … +70 °C | |
Operation Compensated -25 … +55 °C | |
Storage -50 … +80 °C | |
Degree Of Protection | Housing IP20 |
Main Circuit Terminals IP10 | |
Number Of Poles | 3 |
Product Net Width | 45 |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kilovolt |
Rated Operational Current AC-3 (Ie) | 0.63 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 0.18 kW |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 50 kA |
(400 V AC) 50 kA | |
(440 V AC) 50 kA | |
(500 V AC) 30 kA | |
(690 V AC) 30 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA |
(400 V AC) 100 kA | |
(440 V AC) 100 kA | |
(500 V AC) 100 kA | |
(690 V AC) 100 kA | |
Setting Range | 0.40 … 0.63 A |