The AF305-30-11-13 is a 3 pole – 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 160 kW / 400 V AC (AC-3) or 250 hp / 480 V UL and switching power circuits up to 500 A (AC-1) or 400 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
MAIN SPECIFICATION | |
ABB Global ID | ABB1SFL587002R1311 |
Business Area (Master Data) Name | Electrification |
Catalog Description | AF305-30-11-13 Contactor |
Division (Master Data) Name | Smart Power |
EAN | 7.3205E+12 |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt |
acc. to UL/CSA 600 volt | |
SKU ID | 1SFL587002R1311 |
TECHNICAL | |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A |
Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A | |
Holding at Max. Rated Control Circuit Voltage DC 4.5 W | |
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A | |
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A | |
Pull-in at Max. Rated Control Circuit Voltage DC 410 W | |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C) |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 … 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm² | |
Flexible 1×0.75 … 2.5 mm² | |
Solid 2 x 1 … 4 mm² | |
Stranded 1 x 1 …. 4 mm² | |
Connecting Capacity Main Circuit | Flexible 1 x 16 … 240 mm² |
Rigid Al-Cable 1 x 185 … 240 mm² | |
Rigid Cu-Cable 2 x 70 … 185 mm² | |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A | |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
(AC-2 / AC-4) 150 cycles per hour | |
(AC-3) 300 cycles per hour | |
Maximum Mechanical Switching Frequency | 300 cycles per hour |
Mechanical Durability | 5 million |
Operate Time | Between Coil De-energization and NO Contact Opening 37 … 47 ms |
Between Coil Energization and NO Contact Closing 25 … 55 ms | |
Rated Breaking Capacity AC-3 Acc. To IEC 60947-4-1 | 8 x Ie AC-3 |
Rated Frequency (f) | Main Circuit 50 / 60 Hz |
Rated Making Capacity AC-3 Acc. To IEC 60947-4-1 | 10 x Ie AC-3 |
Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 500 A |
(220 V) 2 Poles in Series, 40 °C 500 A | |
(220 V) 3 Poles in Series, 40 °C 500 A | |
Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 400 A |
(220 V) 3 Poles in Series, 40 °C 400 A | |
Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 400 A |
(220 V) 3 Poles in Series, 40 °C 400 A | |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A | |
Short-Circuit Protective Devices | gG Type Fuses 500 A |
Terminal Type | Main Circuit: Bars |
TECHNICAL UL/CSA | |
General Use Rating UL/CSA | (600 V AC) 400 A |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 100 hp |
(208 V AC) Three Phase 100 hp | |
(220 … 240 V AC) Three Phase 125 hp | |
(440 … 480 V AC) Three Phase 250 hp | |
(550 … 600 V AC) Three Phase 300 hp | |
Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Maximum Operating Altitude Permissible | 3000 m |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
CLASSIFICATIONS | |
E-Number (Finland) | 3706486 |
E-Number (Norway) | 4117650 |
E-Number (Sweden) | 3210163 |
EClass | V11.0 : 27371003 |
ETIM 4 | EC000066 – Magnet contactor, AC-switching |
ETIM 5 | EC000066 – Magnet contactor, AC-switching |
ETIM 6 | EC000066 – Power contactor, AC switching |
ETIM 7 | EC000066 – Power contactor, AC switching |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Object Classification Code | Q |
UNSPSC | 39121529 |
OTHER | |
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … +50 °C |
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … +70 °C | |
Close to Contactor for Storage -40 … +70 °C | |
Degree Of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Number Of Main Contacts NO | 3 |
Number Of Poles | 3 |
Product Net Width | 140 |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 … 250 V |
60 Hz 100 … 250 V | |
DC Operation 100 … 250 V | |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kilovolt |
Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 375 ampere |
(1000 V) 55 °C 325 ampere | |
(1000 V) 60 °C 325 ampere | |
(1000 V) 70 °C 260 ampere | |
(690 V) 40 °C 500 No unit | |
(690 V) 55 °C 400 No unit | |
(690 V) 70 °C 325 No unit | |
Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 305 A |
(440 V) 55 °C 305 A | |
(500 V) 55 °C 290 A | |
(690 V) 55 °C 290 A | |
(1000 V) 55 °C 131 A | |
(380 / 400 V) 55 °C 305 A | |
(220 / 230 / 240 V) 55 °C 305 | |
Rated Operational Power AC-3 (Pe) | (415 V) 160 kW |
(440 V) 160 kW | |
(500 V) 200 kW | |
(690 V) 250 kW | |
(1000 V) 185 kW | |
(380 / 400 V) 160 kW | |
(220 / 230 / 240 V) 90 kW | |
Rated Operational Voltage | Main Circuit 1000 V |
Reviews