Sale!

50A , Ith 80A , Magnetic Contactor (MC)-Schneider Electric

Original price was: ৳ 14,150.00.Current price is: ৳ 9,905.00.

& Delivery/Courier Charge
Category:

Free Delivery on orders over ৳50,000!

  • Cash on delivery
  • 1-3 Days Standard Delivery Guaranteed
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel.

Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil.

Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

 

Specifications
Main
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
contactor application Motor control
Resistive load
Utilisation category AC-4
AC-3
AC-1
AC-2
AC-3e
poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
[Ie] rated operational current 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Motor power kW 22 kW at 380…400 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 220…230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
22 kW at 380…400 V AC 50 Hz (AC-3e)
25 kW at 415 V AC 50 Hz (AC-3e)
30 kW at 440 V AC 50 Hz (AC-3e)
30 kW at 500 V AC 50 Hz (AC-3e)
33 kW at 660…690 V AC 50 Hz (AC-3e)
15 kW at 220…230 V AC 50 Hz (AC-3e)
30 kW at 1000 V AC 50 Hz (AC-3e)
Maximum Horse Power Rating 3 hp at 115 V AC 60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phase motors
15 hp at 230/240 V AC 60 Hz for 3 phase motors
40 hp at 460/480 V AC 60 Hz for 3 phase motors
40 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for control circuit
80 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 900 A at 440 V for power circuit conforming to IEC 60947
140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit
Power dissipation per pole 3.7 W AC-3
9.6 W AC-1
3.7 W AC-3e
[Ui] rated insulation voltage Control circuit 600 V CSA
Control circuit 600 V UL
Power circuit 600 V CSA
Power circuit 600 V UL
Control circuit 690 V IEC 60947-1
Power circuit 690 V IEC 60947-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 6000000 cycles
Control circuit type AC 50/60 Hz
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3…0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
Inrush power in VA 140 VA cos phi 0.75 (at 68 °F (20 °C))
160 VA cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 140 °F (60 °C)
Connections – terminals Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) – cable stiffness: rigid
Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) – cable stiffness: rigid
Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Power circuit: screw terminals 1 0.00…0.04 in² (2.5…25 mm²) – cable stiffness: rigid
Power circuit: screw terminals 2 0.00…0.02 in² (2.5…16 mm²) – cable stiffness: rigid
Power circuit: screw terminals 1 0.00…0.04 in² (2.5…25 mm²) – cable stiffness: flexible without cable end
Power circuit: screw terminals 2 0.00…0.02 in² (2.5…16 mm²) – cable stiffness: flexible without cable end
Power circuit: screw terminals 1 0.00…0.04 in² (2.5…25 mm²) – cable stiffness: flexible with cable end
Power circuit: screw terminals 2 0.00…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2
Power circuit 44.25 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2
auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Terminals description ISO n°1 (21-22)NC
(13-14)NO
(A1-A2)CO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Mounting Support Rail
Plate
Environment
Standards UL 508
IEC 60947-5-1
EN 60947-4-1
IEC 60947-4-1
EN 60947-5-1
CSA C22.2 No 14
Product Certifications UL
BV
GL
RINA
CSA
LROS (Lloyds register of shipping)
GOST
DNV
CCC
UKCA
IP degree of protection IP2X IEC 60529
IP2X VDE 0106
Climatic withstand IACS E10 exposure to damp heat
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor opened 10 Gn for 11 ms)
Shocks contactor closed 15 Gn for 11 ms)
Vibrations contactor opened 2 Gn, 5…300 Hz)
Vibrations contactor closed 4 Gn, 5…300 Hz)
Height 5.00 in (127 mm)
Width 2.95 in (75 mm)
Depth 4.69 in (119 mm)
Net Weight 3.09 lb(US) (1.4 kg)
Ordering and shipping details
Category US10I1222357
Discount Schedule 0I12
GTIN 3.38911E+12
Returnability Yes
Country of origin US
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.70 in (9.4 cm)
Package 1 Width 5.51 in (14.0 cm)
Package 1 Length 5.20 in (13.2 cm)
Package 1 Weight 3.19 lb(US) (1.446 kg)
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 5.91 in (15 cm)
Package 2 Width 11.81 in (30 cm)
Package 2 Length 15.75 in (40 cm)
Package 2 Weight 16.54 lb(US) (7.502 kg)
Contractual warranty
Warranty 18 months

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shopping Cart
80A (AC3), 3P, Ith 125A (AC1), MC, Coil : 220/415/110/24 V AC, TeSys D contactor - Schneider Electric50A , Ith 80A , Magnetic Contactor (MC)-Schneider Electric
Original price was: ৳ 14,150.00.Current price is: ৳ 9,905.00.
Scroll to Top