TeSys F contactor, 3 poles (3NO), 500A/1000V AC-3, for motor applications up to 250kW@400V. It provides a low sealed consumption 220V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications | |
Main | |
Range | TeSys |
Range of Product | TeSys F |
Product or Component Type | Contactor |
Device short name | LC1F |
contactor application | Motor control |
Resistive load | |
Utilisation category | AC-1 |
AC-4 | |
AC-3 | |
poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz |
<= 460 V DC | |
[Uc] control circuit voltage | 220 V AC 40…400 Hz |
[Ie] rated operational current | 700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 |
500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 | |
Complementary | |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ith] conventional free air thermal current | 700 A (at 104 °F (40 °C)) |
Rated breaking capacity | 4000 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 4200 A 104 °F (40 °C) – 10 s |
3200 A 104 °F (40 °C) – 30 s | |
2400 A 104 °F (40 °C) – 1 min | |
1500 A 104 °F (40 °C) – 3 min | |
1200 A 104 °F (40 °C) – 10 min | |
Associated fuse rating | 500 A aM at <= 440 V |
800 A gG at <= 440 V | |
Average impedance | 0.18 mOhm – Ith 700 A 50 Hz |
[Ui] rated insulation voltage | 1000 V IEC 60947-4-1 |
1500 V VDE 0110 group C | |
Power dissipation per pole | 88 W AC-1 |
45 W AC-3 | |
Overvoltage category | III |
power pole contact composition | 3 NO |
Motor power kW | 250 kW at 380…400 V AC 50/60 Hz (AC-3) |
280 kW at 415 V AC 50/60 Hz (AC-3) | |
295 kW at 440 V AC 50/60 Hz (AC-3) | |
355 kW at 500 V AC 50/60 Hz (AC-3) | |
335 kW at 660…690 V AC 50/60 Hz (AC-3) | |
335 kW at 1000 V AC 50/60 Hz (AC-3) | |
147 kW at 220…230 V AC 50/60 Hz (AC-3) | |
80 kW at 400 V AC 50/60 Hz (AC-4) | |
Control circuit voltage limits | Operational 0.85…1.1 Uc 40…400 Hz 131 °F (55 °C)) |
Drop-out 0.3…0.5 Uc 40…400 Hz 131 °F (55 °C)) | |
Mechanical durability | 10 Mcycles |
Inrush power in VA | 1100 VA, 40…400 Hz 0.9 68 °F (20 °C)) |
Hold-in power consumption in VA | 18 VA, 40…400 Hz 0.9 68 °F (20 °C)) |
Maximum operating rate | 2400 cyc/h 131 °F (55 °C) |
Operating time | 40…65 ms closing |
100…170 ms opening | |
Connections – terminals | Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end |
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end | |
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end | |
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end | |
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end | |
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end | |
Power circuit bar 2 40 x 5 mm | |
Power circuit lugs-ring terminals 2 0.37 in² (240 mm²) | |
Power circuit bolted connection | |
Tightening torque | Control circuit 10.62 lbf.in (1.2 N.m) |
Power circuit 309.78 lbf.in (35 N.m) | |
Mounting Support | Plate |
Heat dissipation | 18 W |
motor power range | 250…500 kW 380…440 V 3 phase |
110…220 kW 380…440 V 3 phase | |
110…220 kW 200…240 V 3 phase | |
250…500 kW 480…500 V 3 phase | |
Motor starter type | Direct on-line contactor |
Contactor coil voltage | 220 V AC standard |
Standards | EN 60947-4-1 |
IEC 60947-1 | |
EN 60947-1 | |
JIS C8201-4-1 | |
IEC 60947-4-1 | |
Product Certifications | CSA |
CB | |
RMRoS | |
ABS | |
LROS (Lloyds register of shipping) | |
UL | |
RINA | |
BV | |
DNV | |
UKCA | |
Compatibility code | LC1F |
Control circuit type | AC 40…400 Hz |
Environment | |
IP degree of protection | IP20 front face with shrouds IEC 60529 |
IP20 front face with shrouds VDE 0106 | |
Protective treatment | TH |
Ambient air temperature for operation | 23…131 °F (-5…55 °C) |
Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
Permissible ambient air temperature around the device | -40…158 °F (-40…70 °C) |
Height | 9.37 in (238 mm) |
Width | 9.17 in (233 mm) |
Depth | 9.13 in (232 mm) |
Operating altitude | 9842.52 ft (3000 m) without derating |
Net Weight | 25.02 lb(US) (11.35 kg) |
Ordering and shipping details | |
Category | US10I1222336 |
Discount Schedule | 0I12 |
GTIN | 3.38911E+12 |
Returnability | No |
Country of origin | CZ |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 10.83 in (27.5 cm) |
Package 1 Width | 11.81 in (30.0 cm) |
Package 1 Length | 11.81 in (30.0 cm) |
Package 1 Weight | 25.60 lb(US) (11.612 kg) |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 8 |
Package 2 Height | 31.50 in (80.0 cm) |
Package 2 Width | 31.50 in (80.0 cm) |
Package 2 Length | 23.62 in (60.0 cm) |
Package 2 Weight | 223.58 lb(US) (101.412 kg) |
Contractual warranty | |
Warranty | 18 months |
Reviews
There are no reviews yet.