C.BREAKER TMAX XT1C 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A
Circular Value | |
Circular Design Principles Recyclability Rate | Design for Closing Resource Loops – Standard EN45555 – 55.9 % |
Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
End of Life Instructions | 9AKK108468A2347 |
Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
Toxic Substances Control Act – TSCA | 9AKK108467A8326 |
Eco Transparency | |
Environmental Product Declaration – EPD | 9AKK108468A1890 |
9AKK108468A7793 | |
Environmental | |
Environmental Information | 9AKK108467A6707 |
REACH Declaration | 9AKK108466A1425 |
RoHS Information | 9AKK108466A1424 |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
SCIP | 9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy (IT) |
Simplified SCIP | 0baf7834-5c1e-4ab6-92f8-fe1c0c18d111 Germany (DE) |
690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands (NL) | |
1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands (NL) | |
faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany (DE) | |
3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark (DK) | |
adf816cc-8afa-408f-b37f-84d38645b9ce Germany (DE) | |
f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia (HR) | |
a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic (CZ) | |
b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands (NL) | |
678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands (NL) | |
2d166b04-bfde-406d-ae1b-a2d4f9a45c1f Estonia (EE) | |
769c0bf8-bb50-4b05-90d1-f148493e2e93 Greece (GR) | |
c222885d-c4e3-48f8-aa94-67f29ec03c2e Portugal (PT) | |
0fa0c29c-f77e-4742-bd29-9f67a5dd58e7 Bulgaria (BG) | |
3a1ec757-f5bc-4fe2-a796-b80d5848b865 Sweden (SE) | |
3380a59b-f15a-4f8b-8fe2-54d228c70377 Poland (PL) | |
25e84eae-96f0-42ce-9d7d-9dfb5f5ce2a5 France (FR) | |
dafbc307-d434-4abc-8c03-c64d3fc1c333 Sweden (SE) | |
3b414454-d89f-4090-bb59-470a3c7330ea Germany (DE) | |
59695450-664d-4372-9510-6f5c4ac5ad03 Germany (DE) | |
35ec2353-58cd-472a-b909-85aa064a6204 Spain (ES) | |
95a1642c-9a73-4d2e-8a1b-c20ad5fc8a6c Netherlands (NL) | |
5ec14cea-f544-4faa-ab16-fd3819a27732 Poland (PL) | |
ca56bfe2-177d-4ed2-a416-d34db5ca5989 Poland (PL) | |
37ce67d3-3a1a-4ca0-b8ae-7bf5eec07bd9 Finland (FI) | |
3f937e08-97bb-4c73-ac98-fbbab57d1a84 Norway (NO) | |
b394e0ce-ed58-41d4-9e52-9fc27c75e4e8 France (FR) | |
Ordering | |
Order Code US and Canada | XT1CE3100AFF000XXX |
E-Number (Finland) | 3638777 |
EAN | 8.01564E+12 |
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85362090 |
Dimensions | |
Product Net Width | 76.2 mm |
Product Net Height | 130 mm |
Product Net Depth / Length | 70 mm |
Product Net Weight | 1.1 kg |
Container Information | |
Package Level 1 Units | box 1 piece |
Package Level 1 Width | 128 mm |
Package Level 1 Height | 135 mm |
Package Level 1 Depth / Length | 143 mm |
Package Level 1 Gross Weight | 1.136 kg |
Package Level 1 EAN | 8.01564E+12 |
Additional Information | |
Circuit Breaker Type to be Associated | Power Distribution |
Connecting Capacity Main Circuit | Busbar 45.5 … 80 mm² |
Current Type | AC/DC |
Electrical Durability | 120 cycles per hour |
8000 cycle | |
Mechanical Durability | 240 cycles per hour |
25000 cycle | |
Number of Poles | 3 |
Opening Time | CB with SOR 15 ms |
CB with UVR 15 ms | |
Order Multiple | 1 piece |
Power Loss | at Rated Operating Conditions per Pole 7 W |
Product Main Type | SACE Tmax XT |
Product Name | Moulded Case Circuit Breaker |
Product Type | Automatic Circuit Breaker |
Rated Current (In) | 100 A |
Rated Frequency (f) | 50 / 60 Hz |
Rated Voltage (Ur) | 690 V |
Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 1000 A |
Rated Insulation Voltage (Ui) | 800 V |
Rated Operational Voltage | 690 V AC |
500 V DC | |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 40 kA |
(230 V AC) 40 kA | |
(240 V AC) 40 kA | |
(380 V AC) 25 kA | |
(415 V AC) 25 kA | |
(440 V AC) 12.5 kA | |
(500 V AC) 9 kA | |
(525 V AC) 8 kA | |
(690 V AC) 4 kA | |
(250 V DC) 2 Poles in Series 25 kA | |
(500 V DC) 3 Poles in Series 25 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 40 kA |
(230 V AC) 40 kA | |
(240 V AC) 40 kA | |
(380 V AC) 25 kA | |
(415 V AC) 25 kA | |
(440 V AC) 25 kA | |
(500 V AC) 18 kA | |
(525 V AC) 8 kA | |
(690 V AC) 4 kA | |
(250 V DC) 2 Poles in Series 25 kA | |
(500 V DC) 3 Poles in Series 25 kA | |
Rated Uninterrupted Current (Iu) | 160 A |
Recommended Screw Driver | Main Circuit M6 |
Release | TMD |
Release Type | TM |
RoHS Date | NA |
Setting Range | 70…100 A |
Short-Circuit Performance Level | C |
Standards | IEC60947-2 |
Sub-type | XT1 |
Terminal Connection Type | Front |
Terminal Type | Bolt |
Tightening Torque | 6 N·m |
Version | F |
CAD Dimensional Drawing | 1SDH001295R0008 |
Certificates and Declarations | |
ATEX Certificate | No certification needed |
Data Sheet, Technical Information | 1SDC210100D0206 |
1SDC210099D0206 | |
Declaration of Conformity – CE | 9AKK106713A5532 |
GL Certificate | 1SDL000163R0103 |
LR Certificate | 1SDL000163R0100 |
UL Certificate | No certification needed |
VDE Certificate | No certification needed |
Dimension Diagram | 1SDH000719R0100 |
Mechanical Drawings | 1SDH000719R0100 |
Wiring Diagram | 1SDM000068R0001 |
Instructions and Manuals | 1SDH000719R0001 |
Classifications | |
ETIM 7 | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
ETIM 8 | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
ETIM 9 | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q |
UNSPSC | 39120000 |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
eClass | V11.1 : 27370409 |
Reviews