C.BREAKER SACE EMAX2 E6.2V/f 5000 FIXED FOUR-POLE FULL SIZE NEUTRAL WITH TERMINALS REAR HORIZONTAL AND SOLID-STATE RELEASE IN AC EKIP/DIP-LI R 5000 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED
| MAIN SPECIFICATION | |
| ABB Global ID | ABB1SDA071991R1 |
| Business Area (Master Data) Name | Electrification |
| Catalog Description | E6.2V/f 5000 Ekip Dip LI 4p F HR |
| Division (Master Data) Name | Smart Power |
| EAN | 8015644758417 |
| Rated Insulation Voltage (Ui) | AC 1000 volt |
| SKU ID | 1SDA071991R1 |
| TECHNICAL | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 … 690 V 2000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100% |
| Power Loss | 483 W |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Rated Service Short-Circuit Breaking Capacity, In % Of Icu (Ics) | 100% |
| Rated Short-time Withstand Current (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Uninterrupted Current (Iu) | 5000 A |
| Release Type | EL |
| Standards | IEC |
| Sub-type | E6.2 |
| Terminal Connection Type | Rear flat Horizontal |
| ORDERING | |
| Minimum Order Quantity | 1 piece |
| ENVIRONMENTAL | |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| CLASSIFICATIONS | |
| ETIM 4 | EC000228 – Power circuit-breaker for trafo/generator/installation prot. |
| ETIM 5 | EC000228 – Power circuit-breaker for trafo/generator/installation prot. |
| ETIM 6 | EC000228 – Power circuit-breaker for trafo/generator/installation prot. |
| ETIM 7 | EC000228 – Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| OTHER | |
| Number Of Poles | 4 / f |
| Product Net Width | 1014 |
| Rated Current (In) | 5000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kilovolt |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 130 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 130 kA | |
| (525 V AC) 130 kA | |
| (690 V AC) 100 kA | |
| Rated Voltage (Ur) | 690 V |
| Release | Ekip Dip LI |
| Short-Circuit Performance Level | V |
| Version | F |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |