This Altistart 48 soft start/soft stop unit is a controller with 6 thyristors used for torque-controlled soft starting and stopping of three-phase asynchronous motors. It offers soft starting and deceleration functions along with machine and motor protection functions, as well as functions for communicating with control systems. It works at a rated supply voltage from 230V to 415V AC and up to 75A rating. Altistart 48 torque control enables starting without mechanical stress and smooth control of hydraulic transitions, with a single acceleration ramp making adjustments is quick and easy, whatever the load. If connected in the motor supply line it is suitable for motors with power rating up to 37kW (at 400V) for standards applications and 30kW (at 400V) for severe applications.
If connected to the motor delta terminals it is suitable for motors with power rating up to 55kW (at 400V) for standards applications and 55kW (at 400V) for severe applications. It weighs 8.3kg and its dimensions are, 190mm wide, 290mm high, 235mm deep. It is designed for use in the most common applications for centrifugal machines, pumps, fans, compressors and conveyors, which are primarily to be found in the construction, food and beverage and chemical industries. It complies with IEC/EN 60947-4-2 standard and is certified CE, UL, CSA, DNV, C-Tick, GOST, CCC, NOM, SEPRO, and TCF. The Altistart 48 is connected directly to the Modbus bus via its RJ45 connector port,
It can also be connected to Ethernet, Fipio, Profibus DP and DeviceNet networks via a module (bridge or gateway) to order separately. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. Altistart 48 delivers high performance with its Torque Control System (TCS) for controlled starting and deceleration, an easy integration in enclosures and control systems. This range provides also continual improvement of your machine operation by reducing mechanical or hydraulic stress and limiting energy loss and temperature rise, plus more.
Specifications | |
Main | |
Range of product | Altistart 48 |
Product or component type | Soft starter |
Product destination | Asynchronous motors |
Product specific application | Heavy duty industry and pumps |
Device short name | ATS48 |
Utilisation category | AC-53A |
Ue power supply voltage | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % |
Motor power kW | 55 kW at 400 V connection to the motor delta terminals for standard applications |
55 kW at 400 V connection to the motor delta terminals for severe applications | |
15 kW at 230 V connection in the motor supply line for severe applications | |
18.5 kW at 230 V connection in the motor supply line for standard applications | |
30 kW at 230 V connection to the motor delta terminals for severe applications | |
30 kW at 400 V connection in the motor supply line for severe applications | |
37 kW at 230 V connection to the motor delta terminals for standard applications | |
37 kW at 400 V connection in the motor supply line for standard applications | |
Complementary | |
Device connection | To the motor delta terminals |
In the motor supply line | |
Protection type | Phase failure: line |
Thermal protection: motor | |
Thermal protection: starter | |
Standards | EN/IEC 60947-4-2 |
product certifications | DNV |
GOST | |
UL | |
NOM 117 | |
CCC | |
CSA | |
C-Tick | |
TCF | |
SEPRO | |
marking | CE |
Discrete input number | 5 |
Discrete input type | PTC, 750 Ohm at 25 °C |
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | |
Discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
Minimum switching current | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 |
Discrete output type | (LO1) logic output 0 V common configurable |
(LO2) logic output 0 V common configurable | |
(R1) relay outputs fault relay NO | |
(R2) relay outputs end of starting relay NO | |
(R3) relay outputs motor powered NO | |
Analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Communication port protocol | Modbus |
Connector type | 1 RJ45 |
Communication data link | Serial |
Physical interface | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps |
Function available | External bypass (optional) |
Operating position | Vertical +/- 10 degree |
Height | 290 mm |
Width | 190 mm |
Depth | 235 mm |
Product weight | 8.3 kg |
Environment | |
Electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 |
Conducted and radiated emissions level B conforming to IEC 60947-4-2 | |
Damped oscillating waves level 3 conforming to IEC 61000-4-12 | |
Electrostatic discharge level 3 conforming to IEC 61000-4-2 | |
Immunity to electrical transients level 4 conforming to IEC 61000-4-4 | |
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 | |
Voltage/current impulse level 3 conforming to IEC 61000-4-5 | |
Relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) |
-10…40 °C (without derating) | |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | <= 1000 m without derating |
> 1000…2000 m with current derating of 2.2 % per additional 100 m | |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 36 cm |
Package 1 Width | 30.5 cm |
Package 1 Length | 39 cm |
Package 1 Weight | 10.266 kg |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 2 |
Package 2 Height | 73.5 cm |
Package 2 Width | 80 cm |
Package 2 Length | 60 cm |
Package 2 Weight | 33.532 kg |
Contractual warranty | |
Warranty | 18 months |
Reviews
There are no reviews yet.