Specifications | |
Main | |
Range of Product | Altivar Soft Starter ATS480 |
Product or Component Type | Soft starter |
Product destination | Asynchronous motors |
Product Specific Application | Process and infrastructures |
Device short name | ATS480 |
Phase | 3 phase |
Utilisation category | AC-3A |
AC-53A | |
Ue power supply voltage | 208…690 V – 15…10 % |
power supply frequency | 50…60 Hz – 20…20 % |
[Ie] rated operational current | Normal duty 1200.0 A 104 °F (40 °C)) |
rated current in heavy duty | 1045.0 A at 104 °F (40 °C) heavy duty |
Torque control | TRUE |
IP Degree of Protection | IP00 |
Motor power kW | 355.0 kW 230 V in the motor supply line normal duty |
250.0 kW 230 V in the motor supply line heavy duty | |
630.0 kW 400 V in the motor supply line normal duty | |
500.0 kW 400 V in the motor supply line heavy duty | |
710.0 kW 440 V in the motor supply line normal duty | |
630.0 kW 440 V in the motor supply line heavy duty | |
800.0 kW 500 V in the motor supply line normal duty | |
630.0 kW 500 V in the motor supply line heavy duty | |
800.0 kW 525 V in the motor supply line normal duty | |
630.0 kW 525 V in the motor supply line heavy duty | |
900.0 kW 660 V in the motor supply line heavy duty | |
900.0 kW 690 V in the motor supply line heavy duty | |
500.0 kW 230 V to the motor delta terminals normal duty | |
710.0 kW 400 V to the motor delta terminals heavy duty | |
Maximum Horse Power Rating | 400.0 hp 208 V normal duty |
350.0 hp 208 V heavy duty | |
450.0 hp 230 V normal duty | |
350.0 hp 230 V heavy duty | |
1000.0 hp 460 V normal duty | |
800.0 hp 460 V heavy duty | |
1200.0 hp 575 V normal duty | |
1000.0 hp 575 V heavy duty | |
Option card | Communication module Profibus DP V1 |
Communication module Modbus TCP/EtherNet/IP | |
Communication module CANopen daisy chain | |
Communication module CANopen Sub-D | |
Communication module CANopen open style | |
Complementary | |
Device connection | In the motor supply line |
To the motor delta terminals | |
[Us] control circuit voltage | 110…230 V AC 50/60 Hz – 15…10 % |
Apparent power | 0.2 kVA |
Integrated motor overload protection | TRUE |
motor thermal protection class | Class 10E |
Protection type | Phase failure line |
Integrated thermal protection motor | |
Thermal protection starter | |
Current overload motor | |
Underload motor | |
Excessive starting time, locked rotor motor | |
Motor phase loss motor | |
Line supply phase loss line | |
Line supply phase loss motor | |
Thermal protection motor | |
current limiting %In (5 x Ie maximum) | 150…700 % |
[In] Rated current pwr loss specifctn | 1200.0 A |
Power loss static current independent | 25.0 W |
Power loss per device current dependent | 3472.0 W |
Standards | IEC 60947-4-2 |
UL 60947-4-2 | |
IEC 60664-1 | |
Product Certifications | CE |
cULus | |
CCC | |
UKCA | |
RCM | |
EAC | |
DNV | |
ABS | |
BV | |
CCS | |
marking | CE |
CCC | |
UKCA | |
EAC | |
RCM | |
CULus | |
[Uc] control circuit voltage | 24 V DC |
Discrete input number | 4 |
Discrete input type | STOP) logic inputs, 3500 Ohm |
RUN) logic inputs, 3500 Ohm | |
DI3) programmable as logic input, 3500 Ohm | |
DI4) programmable as logic input, 3500 Ohm | |
Input compatibility | STOP discrete input level 1 PLC IEC 61131-2 |
RUN discrete input level 1 PLC IEC 61131-2 | |
DI3 discrete input level 1 PLC IEC 61131-2 | |
DI4 discrete input level 1 PLC IEC 61131-2 | |
Discrete input logic | Programmable digital input < 5 V |
Relay output number | 3 |
Relay output type | Relay outputs R1A 1 NO |
Relay outputs R1B 1 NO | |
Relay outputs RIC NO/NC programmable | |
Minimum switching current | 100 mA 12 V DC relay outputs |
Maximum switching current | Relay outputs 2 A 250 V AC |
Relay outputs 2 A 30 V DC | |
Relay outputs | |
Discrete output number | 2 |
Discrete output type | DQ1) programmable digital output <= 30 V |
DQ2) programmable digital output <= 30 V | |
Output compatibility | Open collector level 1 PLC IEC 65A-68 |
Analogue input number | 1 |
Analogue input type | AI1/PTC PTC/Pt 100 temperature probe |
PTC2 PTC/Pt 100 temperature probe | |
PTC3 PTC/Pt 100 temperature probe | |
Analogue output number | 1 |
Analogue output type | Current output AQ1 0…20 mA or 0…10 V 500 Ohm |
Communication Port Protocol | Modbus serial |
Connector Type | 1 RJ45 |
Communication data link | Serial |
Physical interface | 2-wire RS 485 |
Transmission Rate | 1200…256000 bit/s |
Transmission frame | RTU |
Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance Modbus serial |
Number of addresses | 0…227 Modbus serial |
Method of access | Slave Modbus serial |
Function Available | External bypass control |
Pre-heating | |
Smoke extraction | |
Multi-motor cascade | |
Second motor set | |
User management | |
Ports and services hardening | |
Security event logging | |
Cybersecure firmware update | |
Single direction | |
Display screen available | TRUE |
Operating position | Vertical +/- 10 degree |
Height | 35.04 in (890.0 mm) |
Width | 30.3 in (770.0 mm) |
Depth | 13.0 in (329.0 mm) |
Net Weight | 253.5 lb(US) (115.0 kg) |
Environment | |
Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2 |
Conducted and radiated emissions with bypass level B IEC 60947-4-2 | |
Damped oscillating waves level 3 IEC 61000-4-12 | |
Electrostatic discharge level 3 IEC 61000-4-11 | |
Immunity to electrical transients level 4 IEC 61000-4-4 | |
Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 | |
Voltage/current impulse level 3 IEC 61000-4-5 | |
Pollution degree | Level 3 |
[Uimp] rated impulse withstand voltage | 6 kV |
[Ui] Rated Insulation Voltage | 690 V |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 |
Class 3S2 according to IEC 60721-3-3 | |
Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 |
Ambient air temperature for operation | 104…140 °F (40…60 °C) with current derating of 2 % per °C) |
5…104 °F (-15…40 °C) without derating) | |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Operating altitude | <= 3280.84 ft (1000 m) without derating |
> 3280.84…13123.36 ft (> 1000…4000 m) with current derating 1 % per 100 m | |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
Maximum deflection under vibratory load (during storage) | 1.75 mm at 2…9 Hz |
Maximum deflection under vibratory load (during transport) | 1.75 mm at 2…9 Hz |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
Maximum acceleration under vibratory load (during storage) | 15 m/s² at 200…500 Hz |
10 m/s² at 9…200 Hz | |
Maximum acceleration under vibratory load (during transport) | 15 m/s² at 200…500 Hz |
10 m/s² at 9…200 Hz | |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under shock load (during storage) | 100 m/s² at 11 ms |
Maximum acceleration under shock load (during transport) | 100 m/s² at 11 ms |
Ordering and shipping details | |
Category | US1CP1G22588 |
Discount Schedule | CP1G |
GTIN | 3.60648E+12 |
Returnability | No |
Country of origin | US |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 23.2 in (59.0 cm) |
Package 1 Width | 37.4 in (95.0 cm) |
Package 1 Length | 40.6 in (103.0 cm) |
Package 1 Weight | 297.6 lb(US) (135.0 kg) |
Sale!
Soft starter for asynchronous motor, ATS480, 1200A, 208 to 690V, Control Supply 110 to 230V AC-Schneider Electric
Original price was: ৳ 2,000,000.00.৳ 1,400,000.00Current price is: ৳ 1,400,000.00.
& Delivery/Courier ChargeDocuments: Product datasheet, Instruction sheet, CAD file, Catalogue
Free Delivery on orders over ৳50,000!
- Cash on delivery
- 1-3 Days Standard Delivery Guaranteed
- No-Risk Money Back Guarantee!
- No Hassle Refunds
- Secure Payments
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.