Sale!

MS116-12, Manual Motor Starter – ABB

Original price was: ৳ 10,000.00.Current price is: ৳ 8,000.00.

& Delivery/Courier Charge

Free Delivery on orders over ৳50,000!

  • Cash on delivery
  • 1-3 Days Standard Delivery Guaranteed
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments

The MS116-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Popular Downloads
Data Sheet, Technical Information2CDC131025D0201
Instructions and Manuals2CDC131011M6802
Instructions and Manuals (Part 2)2CDC131060M0202
Time-Current Characteristic Curve1SAM200505F0012
I²t Characteristic1SAM200507F0001
1SAM200507F0002
1SAM200507F0003
Cut-off Current Characteristic1SAM200508F0001
1SAM200508F0002
1SAM200508F0003
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAM200422F0001
Dimensions
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Technical
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 25 kA
(400 V AC) 25 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 15 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)180 A
Setting Range8.0 … 12 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 5.5 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 5.5 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)12:00 AM
Rated Operational Current AC-3 (Ie)12:00 AM
Rated Operational Current AC-3e (Ie)12:00 AM
Rated Frequency (f)Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 1.0 … 2.3 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 12 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability100000 cycle
Mechanical Durability100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 … 2.5 mm²
Flexible 1/2x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 4 mm²
Tightening TorqueMain Circuit 0.8 … 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting Positionany
1 … 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal – Up to 400 V 0 mm
Electrical Conductive Board, Horizontal – Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF
StandardsIEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Technical UL/CSA
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 3 Hp
(208 V AC) Three Phase 3 Hp
(220 … 240 V AC) Three Phase 3 Hp
(440 … 480 V AC) Three Phase 7.5 Hp
(550 … 600 V AC) Three Phase 10 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 11 A
(208 V AC) Three Phase 10.6 A
(220 … 240 V AC) Three Phase 9.6 A
(440 … 480 V AC) Three Phase 11 A
(550 … 600 V AC) Three Phase 11 A
Locked Rotor Amps(200 V AC) Three Phase 73.6 A
(208 V AC) Three Phase 71 A
(220 … 240 V AC) Three Phase 64 A
(440 … 480 V AC) Three Phase 63.5 A
(550 … 600 V AC) Three Phase 64.8 A
General Use Rating UL/CSA(600 V AC) 12 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Tightening Torque UL/CSAMain Circuit 10 in·lb
Environmental
Ambient Air TemperatureAround the Enclosure 0 … +40 °C
Operation -25 … +70 °C
Operation Compensated -25 … +55 °C
Storage -50 … +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 … 150 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS Information1SAA963006-4502
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act – TSCA2CMT2023-006539
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Circular Value
End of Life Instructions1SAC200331H0001
Certificates and Declarations
A2L Certificate – IEC1SAA963000-4601
ABS Certificate1SAA963000-0104
BV Certificate1SAA963000-0204
CB Certificate1SAA963005-2003
1SAA963006-2001
CQC CertificateCQC2011010307506570
CQC2014010307744794
Cut-off Current Characteristic1SAM200508F0001
1SAM200508F0002
1SAM200508F0003
Declaration of Conformity – CCC2.02098E+15
2.02098E+15
Declaration of Conformity – CE1SAD101100-3401
Declaration of Conformity – UKCA1SAD201100-3401
DNV Certificate1SAA963000-0304
DNV GL Certificate1SAA963000-0304
EAC Certificate1SAA963000-2701
GL Certificate1SAA963000-0402
I²t Characteristic1SAM200507F0001
1SAM200507F0002
1SAM200507F0003
KC Certificate1SAA963000-1501
LR Certificate1SAA963000-0505
RMRS Certificate1SAA918000-0704
UL CertificateE137861-20001218
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length95 mm
Package Level 1 Height50 mm
Package Level 1 Gross Weight0.28 kg
Package Level 1 EAN4.01361E+12
Package Level 2 Unitscarton 40 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight11.586 kg
Package Level 2 EAN4.01361E+12
Classifications
Object Classification CodeF
ETIM 4EC000074 – Motor protective circuit-breaker
ETIM 5EC000074 – Motor protective circuit-breaker
ETIM 6EC000074 – Motor protection circuit-breaker
ETIM 7EC000074 – Motor protection circuit-breaker
ETIM 8EC000074 – Motor protection circuit-breaker
eClassV11.0 : 27370401
UNSPSC39121521
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3705821
E-Number (Sweden)3111949

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shopping Cart
MS116-12, Manual Motor Starter – ABB
Original price was: ৳ 10,000.00.Current price is: ৳ 8,000.00.
Scroll to Top