AX09…AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
MAIN SPECIFICATION | |
ABB Global ID | ABB1SBL931074R8010 |
Business Area (Master Data) Name | Electrification |
Catalog Description | AX25-30-10-80 220-230V50Hz/230-240V60Hz Contactor |
Division (Master Data) Name | Smart Power |
EAN | 3471522397805 |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 volt |
SKU ID | 1SBL931074R8010 |
TECHNICAL | |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 32 A |
acc. to IEC 60947-5-1, q = 40 °C 16 A | |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A | |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-3) 1200 cycles per hour | |
(DC-13) 900 cycles per hour | |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Operate Time | Between Coil De-energization and NC Contact Closing 9 … 16 ms |
Between Coil De-energization and NO Contact Opening 4 … 11 ms | |
Between Coil Energization and NC Contact Opening 7 … 21 ms | |
Between Coil Energization and NO Contact Closing 10 … 26 ms | |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Rated Operational Current AC-15 (Ie) | (220 / 240 V) 4 A |
(24 / 127 V) 6 A | |
(400 / 440 V) 2 A | |
(500 V) 2 A | |
(690 V) 2 A | |
(380 / 440 V) 3 A | |
Rated Operational Current DC-13 (Ie) | (110 V) 1.1 A / 121 W |
(220 V) 0.55 A / 121 W | |
(400 V) 2.8 A / 134 W | |
(500 V) 2 A / 144 W | |
(125 V) 1.1 A / 138 W | |
(24 V) 6 A / 144 W | |
(250 V) 0.55 A / 138 W | |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | |
for 0.1 s 140 A | |
for 1 s 100 A | |
Terminal Type | Screw Terminals |
TECHNICAL UL/CSA | |
General Use Rating UL/CSA | (600 V AC) 30 A |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 2 Hp |
(240 V AC) Single Phase 3 Hp | |
(200 … 208 V AC) Three Phase 7.5 Hp | |
(220 … 240 V AC) Three Phase 7.5 Hp | |
(440 … 480 V AC) Three Phase 15 Hp | |
(550 … 600 V AC) Three Phase 15 Hp | |
Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb |
Control Circuit 9 in·lb | |
Main Circuit 11 in·lb | |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Climatic Withstand | acc. to IEC 60068-2-30 and 60068-2-11 – UTE C 63-100 specification II |
Maximum Operating Altitude Permissible | 3000 m |
RoHS Status | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
CLASSIFICATIONS | |
E-Number (Finland) | 3707335 |
ETIM 6 | EC000066 – Power contactor, AC switching |
ETIM 7 | EC000066 – Power contactor, AC switching |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Object Classification Code | Q |
UNSPSC | 39121529 |
OTHER | |
Ambient Air Temperature | Close to Contactor for Storage -60 … +80 °C |
Close to Contactor Fitted with Thermal O/L Relay -25 … +55 °C | |
Close to Contactor without Thermal O/L Relay -40 … +70 °C | |
Near Contactor for Operation in Free Air -40 … +70 °C | |
Degree Of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
Number Of Auxiliary Contacts NO | 1 |
Number Of Main Contacts NO | 3 |
Product Net Width | 44 |
Rated Control Circuit Voltage (Uc) | 50 Hz 220 … 230 V |
60 Hz 230 … 240 V | |
Rated Impulse Withstand Voltage (Uimp) | 6 kilovolt |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 32 ampere |
(690 V) 70 °C 23 ampere | |
(220 / 240 V) 55 °C 27 ampere | |
Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 25 A |
(380 / 400 V) 55 °C 25 A | |
(415 V) 55 °C 25 A | |
(440 V) 55 °C 16 A | |
(500 V) 55 °C 14 A | |
(690 V) 55 °C 10 A | |
Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 6.5 kW |
(380 / 400 V) 11 kW | |
(415 V) 11 kW | |
(440 V) 9 kW | |
(500 V) 9 kW | |
(690 V) 9 kW | |
Rated Operational Voltage | Auxiliary Circuit 690 V |
Main Circuit 690 V |
Reviews