The AF96-30-11-13 is a 3 pole – 1000 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 45 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 130 A (AC-1) or 115 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
MAIN SPECIFICATION | |
ABB Global ID | ABB1SBL407001R1311 |
Business Area (Master Data) Name | Electrification |
Catalog Description | AF96-30-11-13 100-250V50/60HZ-DC Contactor |
Division (Master Data) Name | Smart Power |
EAN | 3471523133334 |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt |
acc. to UL/CSA 600 volt | |
SKU ID | 1SBL407001R1311 |
TECHNICAL | |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² |
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm² | |
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm² | |
Rigid 1/2x 1 … 2.5 mm² | |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² |
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm² | |
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm² | |
Rigid 1/2x 1 … 2.5 mm² | |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 … 50 mm² |
Flexible with Insulated Ferrule 1/2x 6 … 50 mm² | |
Rigid 1x 6 … 70 mm² | |
Rigid 2x 6 … 50 mm² | |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A |
acc. to IEC 60947-5-1, q = 40 °C 16 A | |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A | |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
(AC-15) 1200 cycles per hour | |
(AC-2 / AC-4) 150 cycles per hour | |
(AC-3) 1200 cycles per hour | |
(DC-13) 900 cycles per hour | |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Operate Time | Between Coil De-energization and NC Contact Closing 19 … 105 ms |
Between Coil De-energization and NO Contact Opening 17 … 100 ms | |
Between Coil Energization and NC Contact Opening 38 … 95 ms | |
Between Coil Energization and NO Contact Closing 42 … 100 ms | |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
Main Circuit 50 / 60 Hz | |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
(690 V) 2 A | |
(24 / 127 V) 6 A | |
(220 / 240 V) 4 A | |
(400 / 440 V) 3 A | |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
(48 V) 2.8 A / 134 W | |
(72 V) 1 A / 72 W | |
(110 V) 0.55 A / 60 W | |
(125 V) 0.55 A / 69 W | |
(220 V) 0.27 A / 60 W | |
(250 V) 0.27 A / 68 W | |
(400 V) 0.15 A / 60 W | |
(500 V) 0.13 A / 65 W | |
(600 V) 0.1 A / 60 W | |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A |
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | |
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | |
for 0.1 s 140 A | |
for 1 s 100 A | |
Terminal Type | Screw Terminals |
Wire Stripping Length | Main Circuit 17 mm |
TECHNICAL UL/CSA | |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 7-1/2 hp |
(200 … 208 V AC) Three Phase 30 hp | |
(200 V AC) Three Phase 30 hp | |
(208 V AC) Three Phase 30 hp | |
(220 … 240 V AC) Three Phase 40 hp | |
(240 V AC) Single Phase 40 hp | |
(440 … 480 V AC) Three Phase 75 hp | |
(550 … 600 V AC) Three Phase 75 hp | |
Tightening Torque UL/CSA | Auxiliary Circuit 11 IA |
Control Circuit 11 IA | |
Main Circuit 53 IA | |
ORDERING | |
Minimum Order Quantity | 1 piece |
ENVIRONMENTAL | |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible | 3000 m |
Resistance To Shock Acc. To IEC 60068-2-27 | Closed, Shock Direction: A 25 K40 |
Closed, Shock Direction: B1 25 K40 | |
Closed, Shock Direction: B2 15 K40 | |
Closed, Shock Direction: C1 25 K40 | |
Closed, Shock Direction: C2 25 K40 | |
Open, Shock Direction: B1 5 K40 | |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5 … 300 Hz 3 g closed position / 3 g open position |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
E-Number (Finland) | 3707142 |
EClass | V11.0 : 27371003 |
ETIM 4 | EC000066 – Magnet contactor, AC-switching |
ETIM 5 | EC000066 – Magnet contactor, AC-switching |
ETIM 6 | EC000066 – Power contactor, AC switching |
ETIM 7 | EC000066 – Power contactor, AC switching |
Object Classification Code | Q |
UNSPSC | 39121529 |
OTHER | |
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 … +60 °C |
Close to Contactor without Thermal O/L Relay -40 … +70 °C | |
Close to Contactor for Storage -60 … +80 °C | |
Degree Of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
Number Of Auxiliary Contacts NC | 1 |
Number Of Auxiliary Contacts NO | 1 |
Number Of Main Contacts NO | 3 |
Product Net Width | 82 |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 … 250 V |
50 Hz / 60 Hz 100 … 250 V | |
60 Hz 100 … 250 V | |
DC Operation 100 … 250 V | |
Rated Impulse Withstand Voltage (Uimp) | 8 kilovolt |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 130 No unit |
(690 V) 60 °C 105 ampere | |
(690 V) 70 °C 90 No unit | |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 105 A |
(440 V) 60 °C 105 A | |
(500 V) 60 °C 80 A | |
(690 V) 60 °C 57 A | |
(1000 V) 55 °C 30 A | |
(1000 V) 60 °C 30 A | |
(380 / 400 V) 60 °C 105 A | |
(220 / 230 / 240 V) 60 °C 105 A | |
Rated Operational Power AC-3 (Pe) | (400 V) 55 kW |
(415 V) 55 kW | |
(440 V) 55 kW | |
(500 V) 55 kW | |
(690 V) 55 kW | |
(1000 V) 40 kW | |
(380 / 400 V) 55 kW | |
(220 / 230 / 240 V) 30 kW | |
Rated Operational Voltage | Auxiliary Circuit 690 V |
Main Circuit 1000 V |