Sale!

AF96-30-11-13, Motor Rating 45 kW, Operating Current 96-130A, Magnetic Contactor (MC)- ABB

Original price was: ৳ 50,000.00.Current price is: ৳ 40,000.00.

& Delivery/Courier Charge
Category:

Free Delivery on orders over ৳50,000!

  • Cash on delivery
  • 1-3 Days Standard Delivery Guaranteed
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments

The AF96-30-11-13 is a 3 pole – 1000 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 45 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 130 A (AC-1) or 115 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

MAIN SPECIFICATION
ABB Global IDABB1SBL407001R1311
Business Area (Master Data) NameElectrification
Catalog DescriptionAF96-30-11-13 100-250V50/60HZ-DC Contactor
Division (Master Data) NameSmart Power
EAN3471523133334
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
acc. to UL/CSA 600 volt
SKU ID1SBL407001R1311
TECHNICAL
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Rigid 1/2x 1 … 2.5 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 6 … 50 mm²
Flexible with Insulated Ferrule 1/2x 6 … 50 mm²
Rigid 1x 6 … 70 mm²
Rigid 2x 6 … 50 mm²
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Operate TimeBetween Coil De-energization and NC Contact Closing 19 … 105 ms
Between Coil De-energization and NO Contact Opening 17 … 100 ms
Between Coil Energization and NC Contact Opening 38 … 95 ms
Between Coil Energization and NO Contact Closing 42 … 100 ms
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
for 0.1 s 140 A
for 1 s 100 A
Terminal TypeScrew Terminals
Wire Stripping LengthMain Circuit 17 mm
TECHNICAL UL/CSA
Horsepower Rating UL/CSA(120 V AC) Single Phase 7-1/2 hp
(200 … 208 V AC) Three Phase 30 hp
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 … 240 V AC) Three Phase 40 hp
(240 V AC) Single Phase 40 hp
(440 … 480 V AC) Three Phase 75 hp
(550 … 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSAAuxiliary Circuit 11 IA
Control Circuit 11 IA
Main Circuit 53 IA
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible3000 m
Resistance To Shock Acc. To IEC 60068-2-27Closed, Shock Direction: A 25 K40
Closed, Shock Direction: B1 25 K40
Closed, Shock Direction: B2 15 K40
Closed, Shock Direction: C1 25 K40
Closed, Shock Direction: C2 25 K40
Open, Shock Direction: B1 5 K40
Resistance To Vibrations Acc. To IEC 60068-2-65 … 300 Hz 3 g closed position / 3 g open position
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
E-Number (Finland)3707142
EClassV11.0 : 27371003
ETIM 4EC000066 – Magnet contactor, AC-switching
ETIM 5EC000066 – Magnet contactor, AC-switching
ETIM 6EC000066 – Power contactor, AC switching
ETIM 7EC000066 – Power contactor, AC switching
Object Classification CodeQ
UNSPSC39121529
OTHER
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 … +60 °C
Close to Contactor without Thermal O/L Relay -40 … +70 °C
Close to Contactor for Storage -60 … +80 °C
Degree Of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Number Of Auxiliary Contacts NC1
Number Of Auxiliary Contacts NO1
Number Of Main Contacts NO3
Product Net Width82
Rated Control Circuit Voltage (Uc)50 Hz 100 … 250 V
50 Hz / 60 Hz 100 … 250 V
60 Hz 100 … 250 V
DC Operation 100 … 250 V
Rated Impulse Withstand Voltage (Uimp)8 kilovolt
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 130 No unit
(690 V) 60 °C 105 ampere
(690 V) 70 °C 90 No unit
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 105 A
(440 V) 60 °C 105 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(1000 V) 55 °C 30 A
(1000 V) 60 °C 30 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational Power AC-3 (Pe)(400 V) 55 kW
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(1000 V) 40 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 1000 V

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.