Sale!

AF580-30-11-70, Motor Rating 315kW, Operating Current 580-800A, Magnetic Contactor (MC)- ABB

Original price was: ৳ 266,000.00.Current price is: ৳ 212,800.00.

& Delivery/Courier Charge
Category:

Free Delivery on orders over ৳50,000!

  • Cash on delivery
  • 1-3 Days Standard Delivery Guaranteed
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments
MAIN SPECIFICATION
ABB Global ID ABB1SFL617001R7011
Business Area (Master Data) Name Electrification
Catalog Description AF580-30-11 100-250V 50/60Hz / 100-250V DC Contactor
Division (Master Data) Name Smart Power
EAN 7320500217696
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
acc. to UL/CSA 600 volt
SKU ID 1SFL617001R7011
TECHNICAL
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage DC 5 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
Flexible 2×0.75 … 2.5 mm²
Solid 2 x 1 … 4 mm²
Stranded 1 x 1 …. 4 mm²
Connecting Capacity Main Circuit Bar 52 mm²
Rigid Al-Cable 300 mm²
Rigid Cu-Cable 300 mm²
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 800 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour
(AC-2 / AC-4) 60 cycles per hour
(AC-3) 300 cycles per hour
Maximum Mechanical Switching Frequency 300 cycles per hour
Mechanical Durability 3 million
Operate Time Between Coil De-energization and NC Contact Closing 50 … 70 ms
Between Coil De-energization and NO Contact Opening 53 … 73 ms
Between Coil Energization and NC Contact Opening 45 … 115 ms
Between Coil Energization and NO Contact Closing 50 … 120 ms
Rated Breaking Capacity AC-3 Acc. To IEC 60947-4-1 8 x Ie AC-3
Rated Frequency (f) Main Circuit 50 / 60 Hz
Rated Making Capacity AC-3 Acc. To IEC 60947-4-1 10 x Ie AC-3
Rated Operational Current DC-1 (Ie) (110 V) 1-Pole, 40 °C 800 A
(110 V) 2 Poles in Series, 40 °C 800 A
(220 V) 3 Poles in Series, 40 °C 800 A
(600 V) 3 Poles in Series, 40 °C 800 A
(850 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-3 (Ie) (110 V) 1-Pole, 40 °C 800 A
(110 V) 2 Poles in Series, 40 °C 800 A
(220 V) 3 Poles in Series, 40 °C 800 A
(600 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-5 (Ie) (110 V) 1-Pole, 40 °C 800 A
(110 V) 2 Poles in Series, 40 °C 800 A
(220 V) 3 Poles in Series, 40 °C 800 A
(600 V) 3 Poles in Series, 40 °C 800 A
Rated Short-time Withstand Current (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Short-Circuit Protective Devices gG Type Fuses 1000 A
Terminal Type Main Circuit: Bars
TECHNICAL UL/CSA
General Use Rating UL/CSA (600 V AC) 750 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 200 hp
(208 V AC) Three Phase 200 hp
(220 … 240 V AC) Three Phase 250 hp
(440 … 480 V AC) Three Phase 500 hp
(550 … 600 V AC) Three Phase 600 hp
Maximum Operating Voltage UL/CSA Main Circuit 1000 V
ORDERING
Minimum Order Quantity 1 piece
ENVIRONMENTAL
Maximum Operating Altitude Permissible 3000 m
Resistance To Shock Acc. To IEC 60068-2-27 Shock Direction: A 5 K40
Shock Direction: B1 5 K40
Shock Direction: B2 5 K40
Shock Direction: C1 5 K40
Shock Direction: C2 5 K40
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
CLASSIFICATIONS
E-Number (Finland) 3709334
E-Number (Norway) 4115296
E-Number (Sweden) 3228356
EClass V11.0 : 27371003
ETIM 4 EC000066 – Magnet contactor, AC-switching
ETIM 5 EC000066 – Magnet contactor, AC-switching
ETIM 6 EC000066 – Power contactor, AC switching
ETIM 7 EC000066 – Power contactor, AC switching
IDEA Granular Category Code (IGCC) 4755 >> Contactors
Object Classification Code Q
UNSPSC 39121529
OTHER
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … +50 °C
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … +70 °C
Close to Contactor for Storage -40 … +70 °C
Degree Of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Number Of Auxiliary Contacts NC 1
Number Of Auxiliary Contacts NO 1
Number Of Main Contacts NO 3
Number Of Poles 3
Product Net Width 210
Rated Control Circuit Voltage (Uc) 50 Hz 100 … 250 V
60 Hz 100 … 250 V
DC Operation 100 … 250 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kilovolt
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 800 ampere
(1000 V) 55 °C 700 ampere
(1000 V) 70 °C 580 ampere
(690 V) 40 °C 800 No unit
(690 V) 55 °C 700 No unit
(690 V) 70 °C 580 No unit
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 580 A
(440 V) 55 °C 580 A
(500 V) 55 °C 580 A
(690 V) 55 °C 500 A
(1000 V) 55 °C 250 A
(380 / 400 V) 55 °C 580 A
(220 / 230 / 240 V) 55 °C 580
Rated Operational Power AC-3 (Pe) (415 V) 355 kW
(440 V) 355 kW
(500 V) 400 kW
(690 V) 500 kW
(1000 V) 355 kW
(380 / 400 V) 315 kW
(220 / 230 / 240 V) 160 kW
Rated Operational Voltage Main Circuit 1000 V

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shopping Cart
AF580-30-11-70, Motor Rating 315kW, Operating Current 580-800A, Magnetic Contactor (MC)- ABB
Original price was: ৳ 266,000.00.Current price is: ৳ 212,800.00.
Scroll to Top