The AF460-30-11-70 is a 3 pole – 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

MAIN SPECIFICATION
ABB Global ID ABB1SFL597001R6811
Business Area (Master Data) Name Electrification
Catalog Description AF460-30-11 24-60V DC Contactor
Division (Master Data) Name Smart Power
EAN 7.3205E+12
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
acc. to UL/CSA 600 volt
SKU ID 1SFL597001R6811
TECHNICAL
Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Holding at Max. Rated Control Circuit Voltage DC 5 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 900 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 900 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 900 V·A
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C)
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
Flexible 1×0.75 … 2.5 mm²
Solid 2 x 1 … 4 mm²
Stranded 2 x 1 …. 4 mm²
Connecting Capacity Main Circuit Bar 47 mm²
Rigid Al-Cable 2×240 mm²
Rigid Cu-Cable 240 mm²
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 700 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour
(AC-2 / AC-4) 60 cycles per hour
(AC-3) 300 cycles per hour
Maximum Mechanical Switching Frequency 300 cycles per hour
Mechanical Durability 5 million
Operate Time Between Coil De-energization and NC Contact Closing 45 … 55 ms
Between Coil De-energization and NO Contact Opening 48 … 58 ms
Between Coil Energization and NC Contact Opening 45 … 115 ms
Between Coil Energization and NO Contact Closing 50 … 120 ms
Rated Breaking Capacity AC-3 Acc. To IEC 60947-4-1 8 x Ie AC-3
Rated Frequency (f) Main Circuit 50 / 60 Hz
Rated Making Capacity AC-3 Acc. To IEC 60947-4-1 10 x Ie AC-3
Rated Operational Current DC-1 (Ie) (110 V) 1-Pole, 40 °C 700 A
(110 V) 2 Poles in Series, 40 °C 700 A
(220 V) 3 Poles in Series, 40 °C 700 A
(600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-3 (Ie) (110 V) 1-Pole, 40 °C 700 A
(110 V) 2 Poles in Series, 40 °C 700 A
(220 V) 3 Poles in Series, 40 °C 700 A
(600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-5 (Ie) (110 V) 1-Pole, 40 °C 700 A
(110 V) 2 Poles in Series, 40 °C 700 A
(220 V) 3 Poles in Series, 40 °C 700 A
(600 V) 3 Poles in Series, 40 °C 700 A
Rated Short-time Withstand Current (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Short-Circuit Protective Devices gG Type Fuses 800 A
Terminal Type Main Circuit: Bars
TECHNICAL UL/CSA
General Use Rating UL/CSA (600 V AC) 650 A
Horsepower Rating UL/CSA (200 V AC) Three Phase 150 hp
(208 V AC) Three Phase 150 hp
(220 … 240 V AC) Three Phase 200 hp
(440 … 480 V AC) Three Phase 400 hp
(550 … 600 V AC) Three Phase 500 hp
Maximum Operating Voltage UL/CSA Main Circuit 1000 V
ORDERING
Minimum Order Quantity 1 piece
ENVIRONMENTAL
Maximum Operating Altitude Permissible 3000 m
Resistance To Shock Acc. To IEC 60068-2-27 Shock Direction: A 5 K40
Shock Direction: B1 5 K40
Shock Direction: B2 5 K40
Shock Direction: C1 5 K40
Shock Direction: C2 5 K40
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
CLASSIFICATIONS
E-Number (Norway) 4115290
E-Number (Sweden) 3228342
EClass V11.0 : 27371003
ETIM 4 EC000066 – Magnet contactor, AC-switching
ETIM 5 EC000066 – Magnet contactor, AC-switching
ETIM 6 EC000066 – Power contactor, AC switching
ETIM 7 EC000066 – Power contactor, AC switching
IDEA Granular Category Code (IGCC) 4755 >> Contactors
Object Classification Code Q
UNSPSC 39121529
OTHER
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … +50 °C
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … +70 °C
Close to Contactor for Storage -40 … +70 °C
Degree Of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Number Of Auxiliary Contacts NC 1
Number Of Auxiliary Contacts NO 1
Number Of Main Contacts NO 3
Number Of Poles 3
Product Net Width 186
Rated Control Circuit Voltage (Uc) DC Operation 24 … 60 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kilovolt
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 700 ampere
(1000 V) 55 °C 600 ampere
(1000 V) 60 °C 600 ampere
(1000 V) 70 °C 480 ampere
(690 V) 40 °C 700 No unit
(690 V) 55 °C 600 No unit
(690 V) 70 °C 480 No unit
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 460 A
(440 V) 55 °C 460 A
(500 V) 55 °C 460 A
(690 V) 55 °C 400 A
(1000 V) 55 °C 200 A
(380 / 400 V) 55 °C 460 A
(220 / 230 / 240 V) 55 °C 460
Rated Operational Power AC-3 (Pe) (415 V) 250 kW
(440 V) 250 kW
(500 V) 315 kW
(690 V) 355 kW
(1000 V) 280 kW
(380 / 400 V) 250 kW
(220 / 230 / 240 V) 132 kW
Rated Operational Voltage Main Circuit 1000 V