Specifications | |
Main | |
Range | TeSys |
Range of product | TeSys Deca |
product or component type | Contactor |
Device short name | LC1D |
contactor application | Motor control |
Resistive load | |
Utilisation category | AC-1 |
AC-2 | |
AC-4 | |
AC-3e | |
AC-1 | |
poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz |
[Ie] rated operational current | 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit | |
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit | |
[Uc] control circuit voltage | 48 V AC 50/60 Hz |
Complementary | |
Motor power kW | 30 kW at 380…400 V AC 50 Hz |
37 kW at 500 V AC 50 Hz | |
37 kW at 660…690 V AC 50 Hz | |
18.5 kW at 220…230 V AC 50 Hz | |
30 kW at 415 V AC 50 Hz | |
37 kW at 1000 V AC 50 Hz (AC-3) | |
25 kW at 415 V AC 50 Hz (AC-3) | |
22 kW at 380…400 V AC 50 Hz (AC-3) | |
Motor power hp | 10 hp at 230/240 V AC 60 Hz for 1 phase motors |
20 hp at 200/208 V AC 60 Hz for 3 phases motors | |
20 hp at 230/240 V AC 60 Hz for 3 phases motors | |
40 hp at 460/480 V AC 60 Hz for 3 phases motors | |
50 hp at 575/600 V AC 60 Hz for 3 phases motors | |
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors | |
3 hp at 115 V AC 60 Hz for 1 phase motors | |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 80 A (at 60 °C) for power circuit |
10 A (at 60 °C) for control circuit | |
Irms rated making capacity | 140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 |
140 A AC for control circuit conforming to IEC 60947-5-1 | |
900 A at 440 V for power circuit conforming to IEC 60947 | |
Rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
Associated fuse rating | 125 A gG at <= 690 V coordination type 1 for power circuit |
125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 | |
100 A gG at <= 690 V coordination type 1 for power circuit | |
10 A gG for control circuit conforming to IEC 60947-5-1 | |
Power dissipation per pole | 6.4 W AC-1 |
4.2 W AC-3e | |
9.6 W AC-1 | |
3.7 W AC-3 | |
[Ui] rated insulation voltage | Control circuit: 600 V UL certified |
Power circuit: 600 V CSA certified | |
Power circuit: 600 V UL certified conforming to IEC 60947-1 | |
Control circuit: 690 V conforming to IEC 60947-1 | |
Power circuit: 690 V CSA certified conforming to IEC 60947-1 | |
Control circuit: 600 V CSA certified | |
Overvoltage category | III |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 | |
Mechanical durability | 6000000 cycles |
Control circuit type | AC at 50/60 Hz |
Coil technology | Without built-in bidirectional peak limiting diode suppressor |
Control circuit voltage limits | 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz |
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz | |
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz | |
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz | |
Inrush power in VA | 160 VA cos phi 0.75 (at 20 °C) |
140 VA cos phi 0.75 (at 20 °C) | |
Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
13 VA 60 Hz cos phi 0.3 (at 20 °C) | |
Heat dissipation | 4…5 W at 50/60 Hz for control circuit |
Operating time | 12…26 ms closing |
4…19 ms opening | |
Maximum operating rate | 3600 cyc/h 60 °C |
Connections – terminals | Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid without cable end |
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end | |
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end | |
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end | |
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: rigid | |
Power circuit: screw terminals 2 2.5…16 mm² – cable stiffness: rigid without cable end | |
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end | |
Power circuit: screw terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end | |
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end | |
Power circuit: screw terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end | |
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid | |
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: rigid | |
Tightening torque | Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver Philips No 2 |
Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm | |
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver pozidriv No 2 | |
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm | |
auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Type mirror contact 1 NC conforming to IEC 60947-4-1 |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 | |
Terminals description ISO n°1 | (21-22)NC |
(A1-A2)CO | |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on energisation between NC and NO contacts |
1.5 ms on de-energisation between NC and NO contacts | |
mounting support | Plate |
Plate | |
Environment | |
Standards | CSA C22.2 No 14 |
EN 60947-4-1 | |
EN 60947-5-1 | |
UL 508 | |
IEC 60947-4-1 | |
Product certifications | DNV |
LROS (Lloyds register of shipping) | |
CCC | |
CSA | |
BV | |
UL | |
GL | |
GOST | |
UKCA | |
RINA | |
IP degree of protection | IP2X conforming to VDE 0106 |
IP2X conforming to IEC 60529 | |
Climatic withstand | Conforming to IACS E10 exposure to damp heat |
Operating altitude | 0…3000 m |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Shocks contactor closed (15 Gn for 11 ms) |
Vibrations contactor opened (2 Gn, 5…300 Hz) | |
Vibrations contactor closed (4 Gn, 5…300 Hz) | |
Shocks contactor opened (10 Gn for 11 ms) | |
Height | 127 mm |
Width | 75 mm |
Depth | 119 mm |
net weight | 1.4 kg |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 9.5 cm |
Package 1 Width | 13.2 cm |
Package 1 Length | 14.0 cm |
Package 1 Weight | 1.447 kg |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 5 |
Package 2 Height | 15.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 7.566 kg |
Contractual warranty | |
Warranty | 18 months |
Sale!
65A , Ith 80A , Magnetic Contactor (MC)-Schneider Electric
Original price was: ৳ 17,165.00.৳ 12,015.50Current price is: ৳ 12,015.50.
& Delivery/Courier ChargeDocuments: Product datasheet, Instruction sheet, CAD file
Free Delivery on orders over ৳50,000!
- Cash on delivery
- 1-3 Days Standard Delivery Guaranteed
- No-Risk Money Back Guarantee!
- No Hassle Refunds
- Secure Payments
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.