C.BREAKER SACE EMAX2 E2.2N 1600 FIXED THREE-POLE WITH TERMINALS REAR HORIZONTAL AND SOLID-STATE RELEASE IN AC EKIP/DIP-LI R 1600 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

MAIN SPECIFICATION
ABB Global IDABB1SDA070991R1
Business Area (Master Data) NameElectrification
Catalog DescriptionE2.2N 1600 Ekip Dip LI 3p F HR
Division (Master Data) NameSmart Power
EAN8015644748418
Rated Insulation Voltage (Ui)AC 1000 volt
SKU ID1SDA070991R1
TECHNICAL
Current TypeAC
Electrical DurabilityUe =< 440 V 12000 cycle
Ue = 500 … 690 V 10000 cycle
30 cycles per hour
Mechanical Durability25000 cycle
60 cycles per hour
Power Loss136 W
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
Rated Service Short-Circuit Breaking Capacity, In % Of Icu (Ics)100%
Rated Short-time Withstand Current (Icw)for 1 s 66 kA
for 3 s 50 kA
Rated Uninterrupted Current (Iu)1600 A
Release TypeEL
StandardsIEC
Sub-typeE2.2
Terminal Connection TypeRear flat Horizontal
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
CLASSIFICATIONS
ETIM 4EC000228 – Power circuit-breaker for trafo/generator/installation prot.
ETIM 5EC000228 – Power circuit-breaker for trafo/generator/installation prot.
ETIM 6EC000228 – Power circuit-breaker for trafo/generator/installation prot.
ETIM 7EC000228 – Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
OTHER
Number Of Poles3
Product Net Width276
Rated Current (In)1600 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kilovolt
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
Rated Voltage (Ur)690 V
ReleaseEkip Dip LI
Short-Circuit Performance LevelN
VersionF
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)