System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characterist ics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
MAIN SPECIFICATION | |
ABB Global ID | ABB2CDS252001R0504 |
Business Area (Master Data) Name | Electrification |
Catalog Description | S202-C 50 Miniature Circuit Breaker C-Char.,6kA,50A,2P |
Division (Master Data) Name | Smart Buildings |
EAN | 4016779551045 |
Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 440 volt |
SKU ID | 2CDS252001R0504 |
TECHNICAL | |
Accessories Available | Yes |
Actuator Marking | I / O |
Actuator Material | Insulation Group II, Black, Sealable |
Connecting Capacity | Busbar 10 / 10 mm² |
Flexible with Ferrule 0.75 … 25 mm² | |
Flexible 0.75 … 25 mm² | |
Rigid 0.75 … 35 mm² | |
Stranded 0.75 … 35 mm² | |
Contact Position Indication | Red ON / Green OFF |
Dielectric Test Voltage | 50/60 Hz, 1 min: 2 kV |
Electrical Endurance | 10000 AC cycle |
Energy Limiting Class | 3 |
Frequency (f) | 50 Hz |
Housing Material | Insulation Group II, RAL 7035 |
Installation Size | acc. to DIN 43880 1 |
Mechanical Endurance (Nendu) | 20000 cycle |
Mounting On DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
Mounting Position | Any |
Number Of Protected Poles | 2 |
Overvoltage Category | III |
Pollution Degree | 3 |
Power Loss | 6.5 W |
at Rated Operating Conditions per Pole 3.25 W | |
Power Supply Connection | Arbitrary |
Product Name | Miniature Circuit Breaker |
Product Range | S200 |
Rated Frequency (f) | 50 / 60 Hz |
Recommended Screw Driver | Pozidriv 2 |
Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
Standards | IEC/EN 60898-1 |
IEC/EN 60947-2 | |
UL 1077 | |
Terminal Type | Screw Terminals |
Tightening Torque | 2.8 N·m |
TECHNICAL UL/CSA | |
Connecting Capacity UL/CSA | Busbar 18-8 AWG |
Conductor 18-4 AWG | |
Interrupting Rating Acc. To UL1077 | (110 V DC) 10 kA |
(277 V AC) 6 kA | |
(480Y / 277 V AC) 6 kA | |
Maximum Operating Voltage UL/CSA | 110 V DC |
480Y/277 V AC | |
Tightening Torque UL/CSA | 25 in·lb |
DIMENSIONS | |
Built-In Depth (t2) | 69 mm |
Pole Net Weight | 0.115 kg |
ORDERING | |
Minimum Order Quantity | 1 piece |
Selling Unit Of Measure | piece |
ENVIRONMENTAL | |
Environmental Conditions | 28 cycles |
with 55 °C / 90-96 % | |
and 25 °C / 95-100 % | |
Reference Ambient Air Temperature | 30 °C |
Resistance To Shock Acc. To IEC 60068-2-27 | 25g / 2 shocks / 13 ms |
Resistance To Vibrations Acc. To IEC 60068-2-6 | 5g, 20 cycles at 5 … 150 … 5 Hz with load 0.8 In |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
CN8 | 8536 20 10 |
E-Number (Finland) | 3210550 |
E-Number (Sweden) | 2100570 |
EClass | V11.0 : 27141901 |
EPLAN Catalog Tree | Electrical engineering / Protection devices / General |
EPLAN Function Definition | Circuit breaker / Double circuit-breaker / Double circuit breaker 1_2_3_4 |
ETIM 6 | EC000042 – Miniature circuit breaker (MCB) |
ETIM 7 | EC000042 – Miniature circuit breaker (MCB) |
ETIM 8 | EC000042 – Miniature circuit breaker (MCB) |
Object Classification Code | F |
UNSPSC | 39121614 |
WEEE B2C / B2B | Business To Consumer |
POPULAR DOWNLOADS | |
EPLAN Graphical Macro | 9AKK106713A8115 |
EPLAN Macro | 9AKK106713A8105 |
OTHER | |
Ambient Air Temperature | Operation -25 … +55 °C |
Storage -40 … +70 °C | |
Degree Of Protection | IP20 |
Enclosure with Cover IP40 | |
Input Voltage Type | AC/DC |
Number Of Poles | 2 |
Operational Voltage | Maximum (Incl. Tolerance) 125 V DC |
Maximum (Incl. Tolerance) 440 V AC | |
Minimum 12 V AC | |
Minimum 12 V DC | |
Product Net Width | 35 |
Rated Conditional Short-Circuit Current (Inc) | (230 V) 20 kA |
(400 V) 20 kA | |
Rated Current (In) | 50 A |
Rated Impulse Withstand Voltage (Uimp) | at Sea Level 4 kilovolt |
at 2000 m 5 kilovolt | |
at Sea Level 6.2 kilovolt | |
Rated Operational Voltage | acc. to IEC 60898-1 400 V AC |
acc. to IEC 60947-2 440 V AC | |
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 15 kA |
Rated Short-Circuit Capacity (Icn) | (230 V AC) 6 kA |
(400 V AC) 6 kA | |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 20 kA |
(400 V AC) 10 kA | |
(440 V AC) 10 kA | |
Rated Voltage (Ur) | 400 V AC |
Tripping Characteristic | C |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Width In Number Of Modular Spacings | 2 |