Sale!

65A , Ith 80A , Magnetic Contactor (MC)-Schneider Electric

Original price was: ৳ 17,165.00.Current price is: ৳ 12,015.50.

& Delivery/Courier Charge
Category:

Free Delivery on orders over ৳50,000!

  • Cash on delivery
  • 1-3 Days Standard Delivery Guaranteed
  • No-Risk Money Back Guarantee!
  • No Hassle Refunds
  • Secure Payments
Specifications
Main
Range TeSys
Range of product TeSys Deca
product or component type Contactor
Device short name LC1D
contactor application Motor control
Resistive load
Utilisation category AC-1
AC-2
AC-4
AC-3e
AC-1
poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz
Complementary
Motor power kW 30 kW at 380…400 V AC 50 Hz
37 kW at 500 V AC 50 Hz
37 kW at 660…690 V AC 50 Hz
18.5 kW at 220…230 V AC 50 Hz
30 kW at 415 V AC 50 Hz
37 kW at 1000 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
22 kW at 380…400 V AC 50 Hz (AC-3)
Motor power hp 10 hp at 230/240 V AC 60 Hz for 1 phase motors
20 hp at 200/208 V AC 60 Hz for 3 phases motors
20 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
50 hp at 575/600 V AC 60 Hz for 3 phases motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
3 hp at 115 V AC 60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 80 A (at 60 °C) for power circuit
10 A (at 60 °C) for control circuit
Irms rated making capacity 140 A at 440 V AC for control circuit conforming to IEC 60947-5-1
140 A AC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for control circuit conforming to IEC 60947-5-1
Power dissipation per pole 6.4 W AC-1
4.2 W AC-3e
9.6 W AC-1
3.7 W AC-3
[Ui] rated insulation voltage Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified conforming to IEC 60947-1
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V CSA certified conforming to IEC 60947-1
Control circuit: 600 V CSA certified
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability 6000000 cycles
Control circuit type AC at 50/60 Hz
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
Inrush power in VA 160 VA cos phi 0.75 (at 20 °C)
140 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 20 °C)
13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 12…26 ms closing
4…19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: rigid
Power circuit: screw terminals 2 2.5…16 mm² – cable stiffness: rigid without cable end
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end
Power circuit: screw terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: rigid
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver Philips No 2
Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver pozidriv No 2
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm
auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type mirror contact 1 NC conforming to IEC 60947-4-1
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Terminals description ISO n°1 (21-22)NC
(A1-A2)CO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on energisation between NC and NO contacts
1.5 ms on de-energisation between NC and NO contacts
mounting support Plate
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
UL 508
IEC 60947-4-1
Product certifications DNV
LROS (Lloyds register of shipping)
CCC
CSA
BV
UL
GL
GOST
UKCA
RINA
IP degree of protection IP2X conforming to VDE 0106
IP2X conforming to IEC 60529
Climatic withstand Conforming to IACS E10 exposure to damp heat
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor closed (15 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor opened (10 Gn for 11 ms)
Height 127 mm
Width 75 mm
Depth 119 mm
net weight 1.4 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.5 cm
Package 1 Width 13.2 cm
Package 1 Length 14.0 cm
Package 1 Weight 1.447 kg
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.566 kg
Contractual warranty
Warranty 18 months

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shopping Cart
80A (AC3), 3P, Ith 125A (AC1), MC, Coil : 220/415/110/24 V AC, TeSys D contactor - Schneider Electric65A , Ith 80A , Magnetic Contactor (MC)-Schneider Electric
Original price was: ৳ 17,165.00.Current price is: ৳ 12,015.50.
Scroll to Top